UniFi Access Ultra
Aðgangslesari með innbyggðu hubbi fyrir fullkomna stýringu á einni hurð frá einu tæki.
Athugið. Ekki samhæft með sjálfstæðum Access Hubs.
- (1) Lástengi (12V DC, 1A)
- (1) Inntak fyrir útgöngubeiðni
- Opnun með NFC korti eða UniFi Identity appinu
- Tengist og fær straum um PoE+
- IP55 veðurþol (-30 til 40° C)
- Athugið. Ekki samhæft sjálfstæðum Access Hubs.
Þrívídd og myndbönd
Tækni
Tæknilegir eiginleikar
Upplýsingar úr ETIM gögnum framleiðanda. Vantar þig meira? Hafðu samband við tækniráðgjöf okkar.
| Dimensions | 126 x 45 x 37.45 mm (4.9 x 1.8 x 1.5") |
|---|---|
| NFC Card & Keyfob Access | Yes |
| Mobile Unlock | Yes |
| Weatherproofing | IP55 |
| Maximum User Count | 3,000 |
| Tamper Switch | Yes |
| UL 294 Level | Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I |
| NDAA Compliant | Yes |
| Weight | 140 g (4.9 oz) |
| Enclosure Material | Polycarbonate, aluminum alloy |
| Mount Material | Stainless steel |
| Mounting | Wall mount, gang box mount (Included) Junction box (Optional) |
| Indoor and Outdoor Use | Yes |
| Networking Interface | (1) 10/100 MbE RJ45 port |
| Connectivity | BLE 4.2 Ethernet |
| Power Method | PoE+ UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU |
| Max. Power Consumption | 18W |
| Supported Voltage Range | 44–57V DC |
| ESD/EMP Protection | Air: ± 8kV, contact: ± 4kV |
| Powered Output Relay | Lock: 12V DC, 1A |
| Speaker | Yes (Buzzer) |
| LEDs | R/G/B/W <a href="https://help.ui.com/hc/en-us/articles/25738084762775-UniFi-Access-Understand-Access-Device-LED-Status-Indicators" target="_blank" rel="noopener noreferrer">Learn More</a> |
| Button | (1) Factory reset |
| NFC Frequency | 13.56 Mhz |
| NFC Read Range | < 50 mm (1.95'') |
| NFC Technology | ISO 14443A, 14443B, 15693 NFC Tag 1,2,3,4,5 MIFARE Classic MIFARE Plus Mifare Ultralight MIFARE DESFire |
| PoE Cabling Requirements | Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable. |
| UL 294 Statement | Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits. |
| CAN/ULC-60839-11-1 Grade | Grade assignment: I |
| Certifications | CE, FCC, IC, Anatel: 06371-24-08356, SRRC, UL 294, CAN/ULC-60839-11-1 |
| Document number, and issue date and/or revision level | UA-Ultra, V01 |
| Ambient Operating Temperature | -30 to 40° C (-22 to 104° F) |
| Ambient Operating Humidity | 5 to 90% noncondensing |
| Management Application | Access |
| Software Information | The software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a> |